Sharp Air Conditioner Error Codes
Complete Diagnostic & Troubleshooting Guide
Communication Errors
E0
Indoor/Outdoor Communication Error
- Turn off power and restart system.
- Inspect indoor-to-outdoor wiring connections.
- Check communication cable for damage.
- Replace PCB if communication fails.
E8
Communication Fault (PCB)
- Power cycle the air conditioner.
- Inspect PCB connectors and wiring harness.
- Check for loose or corroded terminals.
- Replace faulty control board if needed.
Sensor Errors
E1
Indoor Sensor Fault
- Inspect room temperature sensor wiring.
- Test thermistor resistance values.
- Check for moisture or corrosion.
- Replace indoor sensor if defective.
E2
Outdoor Sensor Fault
- Inspect outdoor sensor connections.
- Check sensor placement and wiring.
- Measure resistance with multimeter.
- Replace faulty outdoor sensor.
Compressor Protection Errors
E3
Compressor Overload
- Allow compressor to cool down.
- Check refrigerant pressure levels.
- Clean condenser coils for proper airflow.
- Inspect compressor relay and capacitor.
Fan System Errors
E4
Fan Motor Error
- Inspect fan blades for obstruction.
- Check fan motor wiring connections.
- Test fan motor operation.
- Replace motor if malfunctioning.
Memory & Control Errors
E5
EEPROM Failure
- Disconnect power and restart unit.
- Inspect PCB for visible damage.
- Check memory IC connections.
- Replace main control board if needed.
Refrigerant System Errors
E6
Refrigerant Issue
- Inspect for refrigerant leaks.
- Check system pressure levels.
- Ensure proper cooling performance.
- Recharge refrigerant if necessary.
Electrical Protection Errors
E7
Overcurrent Protection
- Check voltage stability.
- Inspect compressor current draw.
- Examine wiring for shorts or damage.
- Reset system after correcting issue.
Important: Electrical and refrigerant repairs should only be performed by a certified HVAC technician.